Define where each bore starts and ends
Identify the entry face in the section view. If a through bore must open at the opposite end, name the exit face and show any restrictions on the passage along the way. If the part opens into a different feature, identify the cavity it must meet. A stepped bore can have a through section with a larger recess from one end. Assign size and axial extent to each section, identify which face each dimension starts from, and show which internal shoulder seats the mating part. Mark any transition radius or relief that the assembly needs to clear.
For a blind bore with a conical drill bottom, the full-diameter wall ends where the cone starts. The drill tip reaches farther into the part. Label both endpoints when the working length and the maximum penetration matter. For a flat or specially shaped bottom, describe the actual geometry required. Autodesk's CAM documentation illustrates the difference between measuring to the drill lip and measuring to the tip. The released drawing governs which limit applies to the finished part. Autodesk drill reference
Tie the bore to the working outside features
The shaft may rotate on an outside journal while the bore guides an insert. Identify the functional reference and have the drawing owner specify the required relationship under the invoked tolerancing standard. Separate that relationship from the bore diameter. A correct inside diameter at one section can occur with an offset center. The precision shaft drawing guide shows how to identify the working features and references before choosing a check.
If minimum wall matters, mark the relevant axial span and circumferential coverage. An outer groove, a reduced journal or the larger portion of a stepped bore can leave a thin section. Half the difference between ideal concentric outside and inside diameters gives the wall for that ideal circular section. On a delivered shaft, offset, shape variation and changes along the length can reduce the local wall. For a blind bore, also specify any required remaining material between the bore bottom and the opposite face. Make clear which surfaces bound each requirement.
Agree how the inspection method will reach the feature
Map each result to the exact diameter section, depth and accessible direction. A probe that enters the bore may still be unable to reach its final cylindrical section with sufficient contact clearance. Ask the supplier to show the effective measuring location relative to the blind bottom, step or lead-in. Some measuring instruments are specifically designed for readings close to a blind bottom. The proposed instrument still needs to suit the actual geometry and tolerance. Mitutoyo blind-hole bore gage bulletin
For a concealed minimum-wall requirement, ask how the method covers the area where a thin section could occur. An industrial CT method can evaluate internal wall thickness when it is suitable for the geometry, material and required uncertainty. If an inspection proposal relies on a sectioned sample or a surrogate, agree whether it is permitted, which locations it represents and what will be checked on production parts. ZEISS guidance on CT wall-thickness measurement
Specify needed edge conditions at the entry, exit or hidden intersection where they affect clearance or assembly. In a drilled through bore, burrs can form at both openings. Identify any internal edge that must be checked, and include a separate delivered cleanliness requirement when chips or films matter. Use the turned-part edge conditions guide for the edge acceptance details. Seco tool development notes on through-hole burrs
Put six decisions into the RFQ
| Item | What to show | What to agree in the quotation |
|---|---|---|
| Passage | Entry and exit faces or blind end, section view and material | Through, blind or stepped arrangement and delivery condition |
| Working size | Diameter and axial extent of each controlled cylindrical section | Start faces, full-diameter depths and where size is evaluated |
| Bottom and seats | Drill point limit, flat bottom, shoulders or reliefs when required | How engagement or seating and any internal break-through restriction are checked |
| Wall and location | Controlled wall regions, relevant external features and bore relationship | Coverage for minimum wall and the reference used for geometry inspection |
| Edge and surface | Required entry, exit or intersection condition and applicable finish or cleanliness | Final-condition checks and access to the relevant area |
| Inspection record | Drawing characteristic IDs, sample stage and reporting needs | Measuring reach, evaluated locations, results and treatment of inaccessible areas |
Compare the depth evidence before approving a sample
In a fictional order, a cylindrical insert must fit into a blind bore until its flange seats against the shaft's entry face. A depth check on the first sample reaches the drill point. The insert stops short of seating. Before deciding how to rework the part, check which depth the report measured and review what the insert contacts. The required depth to the end of the usable cylinder must be shown from the entry face and checked independently of the deepest point. If the drawing also protects material behind the bore, review that boundary before authorizing a deeper cut.
For precision shafts, send the released part section and any relevant mating view with the quote request. Include the required inspection evidence and use the quality page when discussing the proposed checks. Confirm feasibility for the specific drawing before placing the order.